Spectrum Issues

Upgrading Eloquence to version 8

When upgrading Eloquence to version 8 the new library path must be specified in the /ASKPLUS/askplus script file.

Library Paths for HP-UX*:

/opt/eloquence/8.0/lib/pa11_32 # 32-bit PA-RISC 1.1 /opt/eloquence/8.0/lib/pa20_32 # 32-bit PA-RISC 2.0 /opt/eloquence/8.0/lib/pa20_64 # 64-bit PA-RISC 2.0 /opt/eloquence/8.0/lib/hpux32 # 32-bit Itanium (IA-64) /opt/eloquence/8.0/lib/hpux64 # 64-bit Itanium (IA-64)

  • Eloquence 8 Release Notes

On PA-RISC based systems modify the SHLIB_PATH in /ASKPLUS/askplus.

Example:

export SHLIB_PATH=$SHLIB_PATH:/opt/eloquence/8.0/lib/pa20_32:/ASKPLUS

On ITANIUM based systems modify the LD_LIBRARY_PATH in /ASKPLUS/askplus.

Example:

export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:/opt/eloquence/8.0/lib/hpux64:/ASKPLUS


Why is Askplus Abbending after upgrading Spectrum to 10.5

Askplus 8.2.3 (PARISC/ITANIUM) or later must be installed when running Spectrum version 10.5 or later.